Here is the list of video tutorials about dental equipment maintenance available on our YouTube channel. These maintenance video guides are indispensable for those who want to deepen important topics related to the maintenance of dental equipment. In addition, our maintenance video guides are a way to take a look at Silver’s® seriousness and professionalism. In fact, we are certified for the service and maintenance of dental equipment of various brands. Click here to view our many certifications.
All maintenance video guides are in Italian but you can watch them on YouTube and choose to read subtitles in English.
In any case, for more information, contact us by clicking here: in this way, you can send us your request; our call center is available to answer all your questions. In addition, at your disposal, we also offer WhatsApp mode to get fast and effective support.
Finally, also visit the Company page to get to know us better. Consider the opportunity to subscribe to our newsletter: you can receive the active promotions of the moment.
Now, get inspired by our maintenance video guides, listed below. Here is the list of video tutorials – maintenance guides available on our YouTube channel. The guides in video format are indispensable for those who want to deepen important topics related to the maintenance of dental equipment.
Video guide alla manutenzione
Contra-angle maintenance
Maintanance of KaVo SonicFlex pneumatic dental ablator
First, separate the head from the motor and then, proceed to disinfection, without ever spraying the disinfectant directly on the equipment; always better to spray over a cloth that then goes through the two components. If any residue remains, then you can brush the tool with a soft toothbrush under running water.
Morita Dentaport ZX Dental Head Maintenance
First, separate the head from the motor and then, proceed to disinfection, without ever spraying the disinfectant directly on the equipment; always better to spray over a cloth that then goes through the two components. If any residue remains, then you can brush the tool with a soft toothbrush under running water. After that, proceed to lubrication using the correct adapter inserted into the lubricant bottle. Lubricate by pressing for a couple of seconds and, if dirty oil comes out, repeat the procedure.
Dental straight handpiece maintenance
Wear personal protection; Next, proceed to disinfect the instrument using a clean cloth on which you have previously sprayed the disinfectant. If traces of impurities or blood remain, wash the instrument under running water, brushing with a soft-bristled toothbrush.
Pay attention: always use the correct adapter. Then, proceed by grabbing the handpiece with a clean cloth, insert it into the adapter and spray the lubricant for a couple of seconds; Repeat the operation if the oil does not come out clean. Finally, with a clean cloth, remove excess oil. Once this is done, bag the instrument.
Dental head maintenance of the Morita ZX2
Lubricate this head after sixty minutes of continuous use, before lubrication and in any case at least once a day.
After disinfecting with a cloth on which disinfectant has been sprayed, if residues remain, pass the head under running water and brush with soft-bristled toothbrush.
Next, proceed to lubrication of the head. Remember to use the correct adapter: in this case, that of the Morita head.
Once you have chosen the adapter insert the instrument and then press the lubricant for one or two seconds and, if the oil does not come out clean, then repeat operation.
Remove the head and wipe it with a cloth to remove excess oil. Finally, pack everything.
N.B. Only the head is lubricated and not the motor.
Dental turbine maintenance
The turbine must be lubricated every twenty minutes of continuous use, before each sterilization, at least once a day. First wipe a cloth with disinfectant and, if residues remain, pass under running water and brush with a soft-bristled toothbrush.
The turbine must then be inserted into the adapter and press at least a couple of seconds. The operation must be repeated in the event that no transparent oil comes out. Then the adapter is replaced to proceed with the lubrication of the rotor caliper. Press for one or two seconds. Then, remove excess oil.
Micromotor O-ring replacement
Always wear personal protection before maintenance.
Using a dental probe, remove the first o-ring and then the second and third. Take the new O-rings and proceed to insert them one by one, dragging them to their seat. Follow the video well to understand how to proceed correctly.
Perform this replacement at least once a year and always in case of losses.
Red ring dental contrangle mantainance
This video will show you how to properly maintain a red ring contra-angle.
This instrument must be lubricated every sixty minutes of continuous use and in any case at least once a day. Put on personal protective equipment (goggles and gloves) and proceed with disinfection. Do not spray the disinfectant directly on the instrument but on a cloth that must then be passed over the entire contra-angle. If blood or impurity remains, wash the contra-angle under running water by brushing with a soft-bristled toothbrush. Insert the correct adapter and insert the contra-angle on this. Press the lubricant for one or two seconds and if the oil does not come out transparent then repeat the operation. Then, change the adapter to proceed to lubricate the rotor caliper (the one where the cutter is inserted). Insert the clamp into the adapter and press for one or two seconds, repeating if the oil does not come out clean.
Dental contra-angle maintenance with removable head
Remember that you must lubricate this type of contra-angle every 60 minutes of continuous use, before each sterilization and at least once a day. After separating the head from the body and disinfecting with a cloth on which the disinfectant has been sprayed, proceed with lubrication using the appropriate adapter to the head. Repeat the operation several times until the oil comes out transparent. Same thing for the body of the contra-angle.
W&H WS-75 surgical dental contra-angle maintenance
The surgical contra-angle should be disinfected using a cloth on which the disinfectant has been sprayed. Pass the cloth all over the contra-angle. Eventually, if impurities remain, pass the contra-angle under the tap, brushing it with a soft-bristled toothbrush. Then insert the handpiece into the adapter and press one or two seconds. If transparent oil comes out it will not be necessary to repeat the operation. Remove excess oil and then bag the handpiece.
N.B. Blood hemoglobin corrodes the mechanical parts of the contra-angle, spoiling transmission. Then, lubricate immediately after use.
Intraflex blue ring dental contra-angle mantainance
As you can see in this video, always wear personal protection and proceed by disassembling the head from the body, turning the bezel. Then, proceed with the disinfection through a cloth on which the disinfectant has been sprayed, Pass it both on the body and on the head. If traces of blood and impurities remain, pass the instrument under running water and brush with a soft toothbrush. Then use a correct adapter, take the head and insert it into the adapter. Press for a few seconds until the oil comes out transparent. Then proceed to lubrication of the body using another adapter. On this, insert the body, press for a couple of seconds and repeat the operation in case dirty oil comes out. Reassemble the head on the body and with a cloth remove all the excess oil. Then. You can bag the tool.
W&H WS-75 EKM Detachable contra-angle
Wear personal protective gear before proceeding. As you can see in this video, this contra-angle is removable; so, you can break it down and proceed to its maintenance piece by piece. With one hand hold the head and with the other rotate the body. Remove this part and with one hand hold the lower part and with the other the head and pull.
Then, disassemble the contra-angle and proceed with the disinfection through a cloth on which you have previously sprayed the disinfectant. Pass the cloth over all pieces of the instrument.
Now reassemble the contra-angle (watch the video for the correct respective direction of head and body) and you can proceed to lubrication using the correct adapter, in which to insert the instrument. Press for a couple of seconds. If dirt is found, repeat until the oil comes out clean. Then remove the oil residue with a cloth. And the contra-angle is ready to be bagged.